pH 2000-S Bench Top Meter Kit complete with electrode, power adaptor, electrode stand and solutions - USA pH Buffers
View MoreModel No: 500-686 pH 6.86 ±0.02 at 25°C 500ml
Model No: 500-10 pH 10.01 ±0.02 at 25°C 500ml
Model No: 500-12 pH 12.46 ±0.02 at 25°C 500ml
Model No: 501-S pH 4.01 ±0.02 Buffer Solution at 25°C 250ml pH 6.86 ±0.02 Buffer Solution at 25°C 250ml pH 9.18 ±0.02 Buffer Solution at 25°C 250ml 3.33M KCl Internal Reference Solution 250ml
Model No: 502-S pH 4.01 ±0.02 Buffer Solution at 25°C 250ml pH 7.00 ±0.02 Buffer Solution at 25°C 250ml pH 10.01 ±0.02 Buffer Solution at 25°C 250ml 3.33M KCl Internal Reference Solution 250ml
Model No: 503-S 84 uS/cm Conductivity Solution at 25°C 250ml 1413 uS/cm Conductivity Solution at 25°C 250ml 12.88 mS/cm Conductivity Solution at 25°C 250ml 111.8 mS/cm Conductivity Solution at 25°C 250ml
The only pocket meter that directly measures pH in 0.1ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample. *LAQUAtwin Pen includes plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper.
The only pocket meter that directly measures conductivity in 0.12ml sample. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the buffer/standard solution or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample. *LAQUAtwin Pen includes plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper.
The only pocket meter that directly measures conductivity in 0.12ml sample and converts it into salinity or salt concentration. No need for a beaker to calibrate the meter or measure a sample. Just place few drops of the standard or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample. *LAQUAtwin Pen includes plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper.
The only pocket meter that directly measures conductivity and total dissolved solids (TDS) in 0.12ml sample. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample.
HORIBA's unique compact meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop.
The only pocket meter that directly measures potassium ion concentration in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the buffer/standard solution or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample. *LAQUAtwin Pen includes plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper.
The only pocket meter that directly measures nitrate ion and nirate-nitrogen concentrations in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the buffer/standard solution or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample. *LAQUAtwin Pen includes plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper.
The only pocket meter that directly measures sodium ion concentration in 0.3ml sample (or 0.05ml sample with sampling sheet B) and converts it into salinity or NaCl salt concentration. No need for a beaker to calibrate the meter or measure a sample. Just place few drops of the buffer/standard solution or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample. *LAQUAtwin Pen includes plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper.
The only pocket meter that directly measures calcium ion concentration in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample. *LAQUAtwin Pen includes plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper.
Waterproof standard handheld meters with blacklit LCD, shockproof and scratch-resistant non-slip casing Include: - 9652-10D plastic-body, gel-filled pH electrode - pH 4.01, 7.00, 10.01 (60ml) - carry case
'pH Range: -2.000 to 20.000 pH Resolution: 0.1/0.01/0.001 pH Accuracy: ± 0.003 pH pH Buffer Groups: USA, NIST, NIST2, DIN, Custom Calibration Points: Up to 5 (USA, NIST, NIST2)/ Up to 6 (DIN, Custom) ORP Range: ± 2000.0 mV Resolution: 0.1 mV Accuracy: ± 0.2 mV Calibration option: Yes (Up to ± 200 mV) Ion Range: 0.000 μg/L to 9999 g/L Units: μg/L - mg/L - g/L, ppm - ppt, mmol/L - mol/L Resolution: 4 Significant digits Accuracy: ± 0.3% full scale or ± 0.2 mV, whichever is higher Calibration points: Up to 5 Temperature Range: -30.0 to 130.0 °C / -22.0 to 266.0 °F Resolution: 0.1 °C / °F Accuracy: ± 0.5 °C / ± 0.9 °F Calibration Option: Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments) Memory: 2000 Auto Data-Logging: Yes Real Time Clock: Yes Data & Time Stamp: Yes Measurement Modes: Auto Stable / Auto Hold / Real Time Offset & Slope Display: Yes (Segment & Average Slopes) Calibration Alarm Limit: Yes (Programmable: up to 90 days) Auto Shut-Off: Yes (Programmable: up to 30 mins) Electrode Status: On screen display Diagnostic Messages: Yes Password Setting: Yes Software Upgrade: Yes PC / Printer Communication: Phono jack (USB / RS232C) Meter inputs: 2 x BNC, 2 x phono (ATC), DC sockets Display: 5'' custom LCD with backlight and 320 segments Power Requirements: AC adaptor 100~240V, 50/60 Hz Dimensions and Weight: 155 (L) x 150 (W) x 67 (H) mm and 770g
'LAQUA 2000 Series Benchtop pH meter Include: - Electrode stand - 9615S-10D glass-body refillable pH electrode - 502-S (pH 4.01, 7.00, 10.01, 3.33M KCl - 250ml ea)
- WQ-330-K handheld meter - includes meter, 4 x AA batteries, Operating manual and Quick guide packed in carry case - Electrodes and cable to be ordered separately (Please contact our sales team for configuration)